Balancing Valves

AB-QM



- Reduced Costs
- Easy Setting
- Perfect Control
- Two in one
- Compact Design
- Can be controlled by Thermal Actuator and Programmable Thermostat


The AB-QM can be used seperately as an automatic flow limiter valve or as a combined flow limiter and control valve when fitted with an actuator. In addition, the setting is extremely user friendly and reliable, making the AB-QM maintenance free.

The AB-QM valve is the obvious choice for balancing and controlling terminal units such as fan-coils, chilled ceilings and air handling units. For the Commissioning Engineer it is straight forward to set the maximum designed flow - just turn the presetting scale at the desired flow. A built-in diaphragm then maintains a constant low differential pressure across the setting cone on the AB-QM. This ensures that the maximum set flow is not exceeded.

Upgrading the valve
By fitting the AB-QM valve with one of four different types of Danfoss actuators, the AB-QM valve is upgraded to a control valve with full authority supplying both temperature control and flow balancing in one valve. As a result, the AB-QM can be used in all cooling and heating applications.

Due to the low differential pressure across the setting cone it is possible to use small actuators with a low closing force.


AB-QM

Technical data



AB-QM
flow limiters

003Z020100 DN10Without measuring nipples.275 l/hG ½ A
003Z020200 DN15Without measuring nipples.450 l/hG ¾ A
003Z020300 DN20Without measuring nipples.900 l/hG 1 A
003Z020400 DN25Without measuring nipples.1700 l/hG 1¼ A
003Z020500 DN32Without measuring nipples.3200 l/hG 1½ A
003Z021100 DN10With measuring nipples.275 l/hG ½ A
003Z021200 DN15With measuring nipples.450 l/hG ¾ A
003Z021300 DN20With measuring nipples.900 l/hG 1 A
003Z021400 DN25With measuring nipples.1700 l/hG 1¼ A
003Z021500 DN32With measuring nipples.3200 l/hG 1½ A
003Z025100 DN10 LFLow flow version, without measuring nipples.150 l/hG ½ A
003Z025200 DN15 LFLow flow version, without measuring nipples.275 l/hG ¾ A
003Z026100 DN10 LFLow flow version, with measuring nipples.150 l/hG ½ A
003Z026200 DN15 LFLow flow version, with measuring nipples.275 l/hG ¾ A
003Z070000 DN40With measuring nipples7500 l/hG 2 A
003Z070200 DN65With measuring nipples.20000 l/hFlange
003Z070300 DN80With measuring nipples.28000 l/hFlange
003Z070400 DN100With measuring nipples.38000 l/hFlange
003Z070500 DN125With measuring nipples.90000 l/hFlange
003Z070600 DN150With measuring nipples.145000 l/hFlange
003Z071000 DN50With measuring nipples12500 l/h G 2½ A
003Z071100 DN50With measuring nipples12500 l/h Flange


Documentation





Certificates/Declarations
 
EU-Declaration: AB-QM DN 10 - DN 50
Declaration_AB-QM_DN10-50.pdf (0.2 Mb), Literature number: VCC6A102, Language: English, Release date: 10/12 2007
 
EU-Declaration: AB-QM DN 65 - DN 150
Declaration_AB-QM_DN65-150.pdf (0.3 Mb), Literature number: VCC6B102, Language: English, Release date: 23/10 2008
 


Data sheet
 
AB-QM, Automatically balanced combination valves
VDA2W712.pdf (4.0 Mb), Literature number: VDA2W212, Language: UK English, Release date: 03/03 2008
 
AB-QM, Automatically balanced combination valves
VDC6Q202_AB-QM.pdf (5.5 Mb), Literature number: VDC6Q202, Language: English, Release date: 10/03 2009
 
AME 110 NL / AME 120 NL
VDKHC402_AME110NL-120NL.pdf (0.8 Mb), Literature number: VDKHC402, Language: English, Release date: 19/05 2009
 
AME 15 QM
AME15QM_VDLEB102.pdf (0.5 Mb), Literature number: VDLEB102, Language: English, Release date: 21/09 2007
 
AME 55 QM
VDCVA102_AME55 QM.pdf (0.5 Mb), Literature number: VDCVA102, Language: English, Release date: 13/06 2008
 
AMI 140
AMI140_VDKHB102.pdf (0.8 Mb), Literature number: VDKHB102, Language: English, Release date: 17/10 2008
 


Instructions
 
AB-QM (DN 10-50)
VIC5E78Y_AB-QM_DN10-50.pdf (3.4 Mb), Literature number: VIC5E78Y, Language: DK,GB,DE,FR,ES,SE,NL,FI,LV,SI,CN,TR,HU,CZ,PL,RU, Release date: 27/05 2009
 
AB-QM (DN65-100)
VIC6A38Y_AB-QM_DN65-100.pdf (0.6 Mb), Literature number: VIC6A38Y, Language: DK,GB,DE,FR,ES,SE,NL,FI,LV,SI,CN,TR,HU,CZ,PL,RU, Release date: 27/05 2009
 
AB-QM DN 125-150
VIC6C18Y_AB-QM_DN125-150.pdf (0.6 Mb), Literature number: VIC6C18Y, Language: DK,GB,DE,FR,ES,SE,NL,FI,LV,SI,CN,TR,HU,CZ,PL,RU, Release date: 31/07 2008
 
AME 110 NL / AME 120 NL
VILEB302_AME110NL-120NL.pdf (1.0 Mb), Literature number: VILEB302, Language: English, Release date: 19/05 2009
 
AME 15QM
VILEA28C_AME15QM.pdf (1.7 Mb), Literature number: VILEA28C, Language: (8C) DK,GB,DE,FR,ES,NL,FI,CN,PL,RU, Release date: 30/07 2009
 
AME 55 QM
VICVB102_AME55QM.pdf (0.7 Mb), Literature number: VICVB102, Language: English, Release date: 12/06 2008
 
AMI 140
AMI140_VICVA102.pdf (0.8 Mb), Literature number: VICVA102, Language: English, Release date: 05/06 2008
 


Sales Leaflet
 
AB-QM brochure (english)
AB-QM_Brochure_En_.pdf (1.0 Mb), Literature number: VBC6B202, Language: English, Release date: 26/08 2009
 
Application leaflet
VBA6M102_72page-master.pdf (12.1 Mb), Literature number: VBA6M102, Language: English, Release date: 12/12 2008
 
Balancing valves reference projects
Ref_brochure_2007_web.pdf (3.8 Mb), Literature number: VBA5O102, Language: English, Release date: 10/06 2006
 


Technical papers
 
AB-QM Flow Checker
VFC6F202_flowchecker_low.pdf (0.2 Mb), Literature number: VFC6F202, Language: English, Release date: 05/02 2009
 
AB-QM Flow Checker (DN 40-150)
VFC6H202_AB-QM flowchecker_DN40-150.pdf (0.3 Mb), Literature number: VFC6H202, Language: English, Release date: 17/11 2009
 


Accessories



Accessories and Spare Parts, AB-QM
082F107200
082F122600 Thermal actuator for Danfoss automatic flow limiter type AB-QM and for valve type VZL
082F109400 The modulated thermal actuator ABNM is used in direct digital controlled (DDC) systems with 0  10 volt control voltage. ABNM apply both in heating and cooling systems.