Underfloor Heating
Product Range Description

                /The FH-BU is a six-zone floor heating wiring centre for use in systems utilising wireless room thermostats. In addition to providing a structured wiring system for thermal actuators, the FH-BU also incorporates two voltage free heat demand relays that are activated when one or more zones call for heat. The two relay solution allows for separate control of a floor heating zone pump and a boiler. <br/><br/>With this arrangement, the boiler may by used for normal radiator heating and hot water service provision, without the need for external relays.
The FH-BU is a six-zone floor heating wiring centre for use in systems utilising wireless room thermostats. In addition to providing a structured wiring system for thermal actuators, the FH-BU also incorporates two voltage free heat demand relays that are activated when one or more zones call for heat. The two relay solution allows for separate control of a floor heating zone pump and a boiler.

With this arrangement, the boiler may by used for normal radiator heating and hot water service provision, without the need for external relays.
FH-BU
                /These simple to use wireless room thermostats communicate with the FH-BU receiver unit using secure digital RF communication. A manual selector switch allows the user to select between a daytime temperature as set on the thermostat setting dial or Auto. If Auto is selected the thermostat controls at the set temperature during normal day periods and at 5°C below set temperature during night periods. Time control of day and night periods is achieved centrally by means of a timer module built into the FH-BU receiver module.
These simple to use wireless room thermostats communicate with the FH-BU receiver unit using secure digital RF communication. A manual selector switch allows the user to select between a daytime temperature as set on the thermostat setting dial or Auto. If Auto is selected the thermostat controls at the set temperature during normal day periods and at 5°C below set temperature during night periods. Time control of day and night periods is achieved centrally by means of a timer module built into the FH-BU receiver module.
FH-RT
                /The FH-WC is an eight zone floor heating wiring centre for use in systems having hard wired room thermostats. In addition to providing a structured wiring system for zone thermostats and associated thermal actuators, the FH-WC also incorporates two voltage free heat demand relays that are activated when one or more zones call for heat. The two relay solution allows for separate control of a floor heating zone pump and a boiler. With this arrangement, the boiler may by used for normal radiator heating and hot water service provision, without the need for external relays.
The FH-WC is an eight zone floor heating wiring centre for use in systems having hard wired room thermostats. In addition to providing a structured wiring system for zone thermostats and associated thermal actuators, the FH-WC also incorporates two voltage free heat demand relays that are activated when one or more zones call for heat. The two relay solution allows for separate control of a floor heating zone pump and a boiler. With this arrangement, the boiler may by used for normal radiator heating and hot water service provision, without the need for external relays.
FH-WC
                /- Fits SET and MK9 wallplates<br/>- Ideal for service replacement<br/>- Industry standard wallplate<br/>- Convenient user overrides<br/>- Simple GMT/BST time change<br/>- AM/PM or 24 hour display<br/>- Day programme copy facility<br/>- Built-in programmes<br/>- Battery back up<br/><br/><br/>The FP975 full programmer offers a direct plug-in replacement to the Danfoss Randall MK9 range (types 922 & 972), the Danfoss Randall SET5, or any other timeswitch or programmer based on the British Gas standard wallplate.<br/><br/>The FP975 is supplied complete with SET wallplates but is designed to also mount directly onto existing MK9 wallplates without the need for wiring changes. Each unit, which when supplied is configured as a SET replacement, can be re-configured as a MK9 replacement by means of a switch on the rear of the unit.
- Fits SET and MK9 wallplates
- Ideal for service replacement
- Industry standard wallplate
- Convenient user overrides
- Simple GMT/BST time change
- AM/PM or 24 hour display
- Day programme copy facility
- Built-in programmes
- Battery back up


The FP975 full programmer offers a direct plug-in replacement to the Danfoss Randall MK9 range (types 922 & 972), the Danfoss Randall SET5, or any other timeswitch or programmer based on the British Gas standard wallplate.

The FP975 is supplied complete with SET wallplates but is designed to also mount directly onto existing MK9 wallplates without the need for wiring changes. Each unit, which when supplied is configured as a SET replacement, can be re-configured as a MK9 replacement by means of a switch on the rear of the unit.
FP975
                /- 230 volt operation<br/>- Large, easy to read scale<br/>- Locking and limiting as standard<br/>- Electronic anticipator heater<br/>- LED Status indicator<br/><br/><br/>To complement the electro-mechanical models Danfoss Randall produce a range of electronic room thermostats, which have a matching style to that of the RMT. The RET range is based upon a wallplate construction, allowing for ease of installation. <br/><br/>The RET range of electronic thermostats are available in 24V and 230V versions. All models incorporate an electronic anticipator heater to improve thermal performance. The thermostats are available in various configurations, including versions with voltage free contacts and LED status indication. <br/><br/>Included in the range are two special night set-back thermostats, which, by means of an external time clock, can be used to control overnight temperatures at a level 5K below normal day operation. <br/><br/>All RET24 and 230 thermostats require a live and neutral power supply of the appropriate voltage.
- 230 volt operation
- Large, easy to read scale
- Locking and limiting as standard
- Electronic anticipator heater
- LED Status indicator


To complement the electro-mechanical models Danfoss Randall produce a range of electronic room thermostats, which have a matching style to that of the RMT. The RET range is based upon a wallplate construction, allowing for ease of installation.

The RET range of electronic thermostats are available in 24V and 230V versions. All models incorporate an electronic anticipator heater to improve thermal performance. The thermostats are available in various configurations, including versions with voltage free contacts and LED status indication.

Included in the range are two special night set-back thermostats, which, by means of an external time clock, can be used to control overnight temperatures at a level 5K below normal day operation.

All RET24 and 230 thermostats require a live and neutral power supply of the appropriate voltage.
RET230
                /- 230 volt operation<br/>- Large, easy to read scale<br/>- Locking and limiting as standard<br/>- Electronic anticipator heater<br/>- LED Status indicators<br/>- Voltage free contacts<br/>- 5K night set-back<br/><br/><br/>To complement the electro-mechanical models Danfoss Randall produce a range of electronic room thermostats, which have a matching style to that of the RMT. The RET range is based upon a wallplate construction, allowing for ease of installation. <br/><br/>The RET range of electronic thermostats are available in 24V and 230V versions. All models incorporate an electronic anticipator heater to improve thermal performance. The thermostats are available in various configurations, including versions with voltage free contacts and LED status indication. <br/><br/>Included in the range are two special night set-back thermostats, which, by means of an external time clock, can be used to control overnight temperatures at a level 5K below normal day operation. <br/><br/>All RET24 and 230 thermostats require a live and neutral power supply of the appropriate voltage.
- 230 volt operation
- Large, easy to read scale
- Locking and limiting as standard
- Electronic anticipator heater
- LED Status indicators
- Voltage free contacts
- 5K night set-back


To complement the electro-mechanical models Danfoss Randall produce a range of electronic room thermostats, which have a matching style to that of the RMT. The RET range is based upon a wallplate construction, allowing for ease of installation.

The RET range of electronic thermostats are available in 24V and 230V versions. All models incorporate an electronic anticipator heater to improve thermal performance. The thermostats are available in various configurations, including versions with voltage free contacts and LED status indication.

Included in the range are two special night set-back thermostats, which, by means of an external time clock, can be used to control overnight temperatures at a level 5K below normal day operation.

All RET24 and 230 thermostats require a live and neutral power supply of the appropriate voltage.
RET230NSB
                /- 230 volt operation<br/>- Large, easy to read scale<br/>- Locking and limiting as standard<br/>- Accelerator heater<br/><br/><br/>The RMT230 room thermostat is suitable for the control of heating, ventilation and air conditioning in 230 volt systems.<br/><br/>The RMT230 has a built in accelerator heater to improve control accuracy.
- 230 volt operation
- Large, easy to read scale
- Locking and limiting as standard
- Accelerator heater


The RMT230 room thermostat is suitable for the control of heating, ventilation and air conditioning in 230 volt systems.

The RMT230 has a built in accelerator heater to improve control accuracy.
RMT230
                /- 230 volt operation<br/>- Large, easy to read scale<br/>- Locking and limiting as standard<br/>- Accelerator heater<br/>- Built-in thermometer<br/>- 5K night set-back<br/><br/><br/>The RMT230T room thermostat is suitable for the control of heating, ventilation and air conditioning in 230 volt systems.<br/><br/>The RMT230T has a built in accelerator heater to improve control accuracy, a built-in thermometer and a night set-back feature.
- 230 volt operation
- Large, easy to read scale
- Locking and limiting as standard
- Accelerator heater
- Built-in thermometer
- 5K night set-back


The RMT230T room thermostat is suitable for the control of heating, ventilation and air conditioning in 230 volt systems.

The RMT230T has a built in accelerator heater to improve control accuracy, a built-in thermometer and a night set-back feature.
RMT230T
                /- Stylish modern design<br/>- Large easy to read LCD display<br/>- Easy to programme and operate<br/>- Battery powered for ease of installation<br/>- Service interval function<br/>- Factory set clock<br/>- Automatic BST/GMT time change<br/>- Hard wired model<br/>- Many additional features<br/><br/><br/>The TP5000 Si is an easy to install-and-use 5/2 day programmable room thermostat which offers up to six time and temperature changes each day with different programmes for weekdays and weekends.<br/><br/>Battery powered for ease of installation, the TP5000 Si has a large, easy-to-read LCD display. It is easy to programme and operate because of a built-in switching programme that the user can easily change to suit individual heating requirements. A big plus with the TP5000 Si is that it incorporates a real time clock and calendar function which eliminates the need for time-setting and BST/GMT time changes. Time and date are factory-set making time setting or adjustment unnecessary.<br/><br/>Conventional On/Off control is the standard setting for the TP5000 Si but advanced chrono-proportional control is an installer-set option. This modulating control mode uses a cycling pattern within which boiler on/off percentages are varied to satisfy heating requirements.<br/>Chrono-proportional cycling rates of 3, 6, 9 or 12 per hour can be selected.<br/><br/>Service Interval function<br/>The optional Service Interval function incorporated into the TP5000 Si helps landlords meet the boiler servicing requirements of Gas Safety Regulation 36. The unit provides audible and visual warnings from 28 days before servicing is due and ultimately reduces the heating output should the due date pass. Full heating operation can only be restored by an authorised installer.
- Stylish modern design
- Large easy to read LCD display
- Easy to programme and operate
- Battery powered for ease of installation
- Service interval function
- Factory set clock
- Automatic BST/GMT time change
- Hard wired model
- Many additional features


The TP5000 Si is an easy to install-and-use 5/2 day programmable room thermostat which offers up to six time and temperature changes each day with different programmes for weekdays and weekends.

Battery powered for ease of installation, the TP5000 Si has a large, easy-to-read LCD display. It is easy to programme and operate because of a built-in switching programme that the user can easily change to suit individual heating requirements. A big plus with the TP5000 Si is that it incorporates a real time clock and calendar function which eliminates the need for time-setting and BST/GMT time changes. Time and date are factory-set making time setting or adjustment unnecessary.

Conventional On/Off control is the standard setting for the TP5000 Si but advanced chrono-proportional control is an installer-set option. This modulating control mode uses a cycling pattern within which boiler on/off percentages are varied to satisfy heating requirements.
Chrono-proportional cycling rates of 3, 6, 9 or 12 per hour can be selected.

Service Interval function
The optional Service Interval function incorporated into the TP5000 Si helps landlords meet the boiler servicing requirements of Gas Safety Regulation 36. The unit provides audible and visual warnings from 28 days before servicing is due and ultimately reduces the heating output should the due date pass. Full heating operation can only be restored by an authorised installer.
TP5000 Si
                /- True 7 day programming<br/>- 7 day or 5/2 day operation<br/>- Up to 6 time and temperature changes per day<br/>- Built in holiday function<br/>- Selectable Optimum Start Control<br/>- On/Off or chrono-proportional regulation<br/>- Convenient user overrides<br/>- Wallplate construction<br/>- Battery powered<br/><br/><br/>The aesthetically pleasing TP7000 programmable room thermostat includes many features making it ideal for in situations where a higher flexibility of control is required.<br/><br/>This battery powered model provides true 7 day programming options, with up to six time and temperature events being available each day. In addition to programmed set-back, this model can be set to turn the heating off if so desired. <br/><br/>To improve comfort and economy the TP7000 offers optional chrono-proportional control and optimum start control. These features are configured by the installer during commissioning.<br/><br/>For the user, many overrides including a 99 day holiday programme provide easy day to day use reducing the likelihood of call-backs.
- True 7 day programming
- 7 day or 5/2 day operation
- Up to 6 time and temperature changes per day
- Built in holiday function
- Selectable Optimum Start Control
- On/Off or chrono-proportional regulation
- Convenient user overrides
- Wallplate construction
- Battery powered


The aesthetically pleasing TP7000 programmable room thermostat includes many features making it ideal for in situations where a higher flexibility of control is required.

This battery powered model provides true 7 day programming options, with up to six time and temperature events being available each day. In addition to programmed set-back, this model can be set to turn the heating off if so desired.

To improve comfort and economy the TP7000 offers optional chrono-proportional control and optimum start control. These features are configured by the installer during commissioning.

For the user, many overrides including a 99 day holiday programme provide easy day to day use reducing the likelihood of call-backs.
TP7000
                /- Service interval function<br/>- 7 day, 5/2 day or 24 hour programming<br/>- Permanent back lit display<br/>- AM/PM or 24 hour display<br/>- Built-in programmes<br/>- Automatic BST/GMT time change<br/>- Convenient user overrides<br/>- Holiday function<br/>- Industry standard wallplate<br/>- Factory set clock<br/><br/><br/>The TS715 Si single channel electronic timeswitch provides voltage free output contacts making it an ideal solution for use with both line voltage and low voltage control circuits.  <br/>  <br/>It is an ideal solution for combi-boilers, for systems having a common Heating and Hot Water zone, and for the control of additional heating zones.<br/><br/>The TS715 Si can be configured by the installer at time of installation to provide 7 day, 24 hour, or 5 day/2 day operation and either 2 ON/OFF's or 3 ON/OFF's per day, allowing the timeswitch to be tailored to match the specific requirement of the consumer.<br/><br/>The wallplate used follows the industry standard pattern, as used by many of the other time control manufacturers. This allows for direct replacement often without the need for re-wiring.<br/><br/>An additional range of accessories allow the TS715 Si to be used in other upgrade situations where the unit being replaced is larger than the new unit and a decoration scar would normally have been left.<br/><br/>Additional features such as service interval timer, convenient user overrides, built-in ready-to-use programmes, a day programme copy facility as well as a stylish, compact design and easy to read display make the TS715 Si the simple answer to all heating and hot water requirements. <br/>
- Service interval function
- 7 day, 5/2 day or 24 hour programming
- Permanent back lit display
- AM/PM or 24 hour display
- Built-in programmes
- Automatic BST/GMT time change
- Convenient user overrides
- Holiday function
- Industry standard wallplate
- Factory set clock


The TS715 Si single channel electronic timeswitch provides voltage free output contacts making it an ideal solution for use with both line voltage and low voltage control circuits.

It is an ideal solution for combi-boilers, for systems having a common Heating and Hot Water zone, and for the control of additional heating zones.

The TS715 Si can be configured by the installer at time of installation to provide 7 day, 24 hour, or 5 day/2 day operation and either 2 ON/OFF's or 3 ON/OFF's per day, allowing the timeswitch to be tailored to match the specific requirement of the consumer.

The wallplate used follows the industry standard pattern, as used by many of the other time control manufacturers. This allows for direct replacement often without the need for re-wiring.

An additional range of accessories allow the TS715 Si to be used in other upgrade situations where the unit being replaced is larger than the new unit and a decoration scar would normally have been left.

Additional features such as service interval timer, convenient user overrides, built-in ready-to-use programmes, a day programme copy facility as well as a stylish, compact design and easy to read display make the TS715 Si the simple answer to all heating and hot water requirements.
TS715 Si
                /In systems that require a common set back time, timed set back can be achieved using an UF-H timer interface card and a standard voltage free timeswitch. In systems where different times are required in selected zones a two channel timer with voltage free contacts must be used. If a two channel timer is used channel one is assigned to zones 1, 3 & 5, (plus 7 if pump control has not been assigned to it). Channel two is assigned to zones 2, 4 & 6, (plus 8 if boiler control has not been assigned to it)<br/><br/>The UH-F timer interface card is supplied as an accessory and is mounted inside the FH-BU front case by the installer.
In systems that require a common set back time, timed set back can be achieved using an UF-H timer interface card and a standard voltage free timeswitch. In systems where different times are required in selected zones a two channel timer with voltage free contacts must be used. If a two channel timer is used channel one is assigned to zones 1, 3 & 5, (plus 7 if pump control has not been assigned to it). Channel two is assigned to zones 2, 4 & 6, (plus 8 if boiler control has not been assigned to it)

The UH-F timer interface card is supplied as an accessory and is mounted inside the FH-BU front case by the installer.
UF-H